-
GRADUATE STUDIES
- • STUDYING AT MANUTECH SLEIGHT
-
MSc in Optics, Image, Vision, Multimedia (OIVM)
-
iPSRS - Intelligent Photonics for Security, Reliability, Sustainability and Safety
- PSRS - Partner universities
- RADMEP - Radiation and its Effects on MicroElectronics and Photonics Technologies
- COSI - Computational Colour and Spectral Imaging
- IMLEX - Imaging & Light in Extended Reality
- AIMA - Advanced Imaging & Material Appearance
- PE - Photonics Engineering
-
iPSRS - Intelligent Photonics for Security, Reliability, Sustainability and Safety
- MSc in Computer Science
- MSc in Health Engineering
- Engineering schools' research tracks
- Doctoral studies
- Training through research
- Opportunities
- Admission and aid
- OPTICA and SPIE Student Chapters
-
RESEARCH & INNOVATION
-
SCIENTIFIC EVENTS
- News and about
-
The SLEIGHT Science Events
- SSE #14 - Metallic surfaces: texturing, functionalization, appearance"
- SSE #13 - SLEIGHT in 2025
- SSE #12 - Imaging in Manutech-SLEIGHT
- SSE #11 - SLEIGHT in 2024
- SSE #10 - Sustainable Surface Engineering
- SSE #09 - SLEIGHT in 2023
- SSE #08 - Photonics for Health
- SSE #07 - SLEIGHT in 2022
- SSE #06 - Machine Learning
- SSE #05 - SLEIGHT in 2021
- SSE #03 - SLEIGHT in 2020
- SSE #02 - Material Appearance
- SSE #01 - Topics and stakeholders
- Manutech-SLEIGHT Awards
- Scientific conferences
- Events in partnership with Manutech-SLEIGHT
- CAMPUS LIFE
- ABOUT US
- NEWSLETTER
You are here : EUR MANUTECH SLEIGHT > SLEIGHT's research projects > LASIMP
-
Partager cette page
Research
Steve PAPA and the SAINBIOSE team publish in Scientific Report
On The September 25, 2023
Steve Papa, PhD student at the SAINBIOSE lab working on the LASIMP project, publishes a new article on bacterial surface adhesion in Scientific Report 13
Steve and the LASIMP project team have published a brand new article in Scientific Report. Our congratulations to the team and to Steve, who will soon defend his thesis.
ABSTRACT
Dental implant failure is primarily due to peri-implantitis, a consequence of bacterial biofilm formation. Bacterial adhesion is strongly linked to micro-/nano-topographies of a surface; thus an assessment of surface texture parameters is essential to understand bacterial adhesion. In this study, mirror polished titanium samples (Ti6Al4V) were irradiated with a femtosecond laser (fs-L) at a wavelength of 1030 nm (infrared) with variable laser parameters (laser beam polarization, number, spacing and organization of the impacts). Images of 3-D topographies were obtained by focal variation microscopy and analyzed with MountainsMap software to measure surface parameters. From bacteria associated with peri-implantitis, we selected Porphyromonas gingivalis to evaluate its adhesion on Ti6Al4V surfaces in an in vitro study. Correlations between various surface parameters and P. gingivalis adhesion were investigated. We discovered that Sa value, a common measure of surface roughness, was not sufficient in describing the complexity of these fs-L treated surfaces and their bacterial interaction. We found that Sku, density and mean depths of the furrows, were the most accurate parameters for this purpose. These results provide important information that could help anticipate the bacterial adhesive properties of a surface based on its topographic parameters, thus the development of promising laser designed biofunctional implants.
Papa, S., Maalouf, M., Claudel, P. et al. Key topographic parameters driving surface adhesion of Porphyromonas gingivalis. Sci Rep 13, 15893 (2023).
doi.org/10.1038/s41598-023-42387-5
ABSTRACT
Dental implant failure is primarily due to peri-implantitis, a consequence of bacterial biofilm formation. Bacterial adhesion is strongly linked to micro-/nano-topographies of a surface; thus an assessment of surface texture parameters is essential to understand bacterial adhesion. In this study, mirror polished titanium samples (Ti6Al4V) were irradiated with a femtosecond laser (fs-L) at a wavelength of 1030 nm (infrared) with variable laser parameters (laser beam polarization, number, spacing and organization of the impacts). Images of 3-D topographies were obtained by focal variation microscopy and analyzed with MountainsMap software to measure surface parameters. From bacteria associated with peri-implantitis, we selected Porphyromonas gingivalis to evaluate its adhesion on Ti6Al4V surfaces in an in vitro study. Correlations between various surface parameters and P. gingivalis adhesion were investigated. We discovered that Sa value, a common measure of surface roughness, was not sufficient in describing the complexity of these fs-L treated surfaces and their bacterial interaction. We found that Sku, density and mean depths of the furrows, were the most accurate parameters for this purpose. These results provide important information that could help anticipate the bacterial adhesive properties of a surface based on its topographic parameters, thus the development of promising laser designed biofunctional implants.
Papa, S., Maalouf, M., Claudel, P. et al. Key topographic parameters driving surface adhesion of Porphyromonas gingivalis. Sci Rep 13, 15893 (2023).
doi.org/10.1038/s41598-023-42387-5
To read as well
- 12 FÉVR6 Manutech-SLEIGHT-funded projects are now completed
Vincent Duveiller, Samaneh Choupani, Eduardo Brandao, Steve Papa, Rehan Jhuboo and Ilemona Sunday Omeje have defended their thesis and completed their project.
- 12 FÉVREMIL: Ilemona OMEJE (LabHC) defended his thesis on February 12th, 2024
Ilemona Sunday OMEJE, former PhD student at the Hubert Curien laboratory, sucessfully defended his thesis!
- 10 JANVMALBOT: Rehan JHUBOO (LabHC) defended his thesis during the SSE#11
Rehan Jhuboo, former PhD student at the Hubert Curien laboratory, sucessfully defended his thesis!